Product introduction
| Product Introduction |
| N180° male to SMA180° male |
| Cable: ALSR200 flexible RF cable |
| Interface Type: SMA&N |
| Cable length: 5cm~200cm (length can be customized) |
| ALSR200 the parameter description of coaxial cable | ||
| 1. Core parameters | ||
| parameter | Typical values | standard |
| characteristic impedance | 50 Ω±0.8% | Precise matching of all frequency bands |
| Outside diameter | 2.8mm±0.10mm | Ultra-fine and flexible (bending radius 8mm static) |
| Central conductor | 42×0.05mm gold-plated copper-magnesium alloy stranded wire | The bending resistance > 2 million times |
| Insulation | Nano-ceramic reinforced PTFE | Temperature resistance level -70°C~+260°C |
| shielding | Third floor: - Gilded copper foil wrap bag - 84 braided gilded copper mesh - Tensile aramid yarn | Shield >110dB@18GHz Tensile strength ≥ 500N |
| jacket | Silicone rubber-polyimide composite layer | Oil/arc/low outgassing |
| weight | 12g/m | 35% lighter than comparable cables |
| 2. Power and frequency characteristics | ||
| frequency | Average power | Pulse power |
| 2GHz | 120W | 5kW |
| 18GHz | 35W | 1.2kW |
| 40GHz | 18W | 0.6kW |
| 3. Extreme environment verification | ||
| Test items | standard | outcome |
| High temperature life | 260°C/1000h aging | Attenuation Change<2% |
| Cryogenic bending | -65°C/8mm radius bending | The sheath is not cracked |
| Resistant to hydraulic oil | IRM 903 Oil Immersion/168h | Tensile strength retention> 95% |
| Flame retardant | UL 1685 FT4 class | The flame spread rate < 1.5m/min |
| Vacuum venting | ESA ECSS-Q-ST-70-02C | TML<0.15% CVCM<0.01% |
| 2. Typical applicable scenarios |
| 1. Airborne phased array radar |
| 2. Joint wiring for industrial robots |
| 3. High temperature furnace sensor |
| Selection guide | |||||
| 1. Specifications and characteristics of commonly adapted cables | |||||
| Model | Outside diameter | Central conductor | 3GHz loss | peculiarity | Applicable scenarios |
| RG-174 | 2.8mm | 7*0.16mm | 0.82dB/m | Flexible, easy to install, and low cost | Consumer electronics |
| RG-316 | 2.6mm | 7*0.1mm | 0.84dB/m | High temperature resistance, military industry standards | High temperature environment, test instruments |
| Micro foamed PE wire | 1.5~2.2mm | 0.3~0.5mm | 0.50dB/m | High frequency loss is low | 5G/Wi-Fi |
| Semi-steel wire | 1.0~3.0mm | Solid copper | 0.30dB/m | Relatively stable and good shielding | Test calibration, mmWave front |
| 2. Comparison of key parameters and selection logic | ||||
| 2.1 Electrical performance priority | ||||
| parameter | RG-174 | RG-316 | Foamed PE wire | effect |
| Attenuation @6GHz | 1.8dBm/m | 1.7dBm/m | 0.9dBm/m | High-frequency signal integrity |
| Shielding efficiency | 70dB | 90dB | >90dB | Anti-interference ability |
| Impedance stability | ±3Ω | ±2Ω | ±1Ω | Reflected signal suppression |
| 2.2 Mechanical and environmental adaptability | |||
| parameter | RG-174 | RG-316 | Foamed PE wire |
| Minimum bend radius | 15mm | 25mm | 30mm |
| Temperature range | -40℃~+85℃ | -65℃~+200℃ | -50℃~+85℃ |
| tensile strength | medium | high | Low (easily damaged) |
| 3. Typical application scenarios are matched with cables |
| 3.1 Consumer Electronics (Bluetooth/Wi-Fi) |
| Cable: RG-174 |
| Reason: Cost sensitive, frequency ≤ 5GHz, short length (<0.3m) and controllable loss. |
| 3.2 Test Instrument Jumper (Vector Network Analyzer) |
| Cable: RG-316 or low-loss foam cable (e.g. Times LMR-200) |
| Reason: It needs to be resistant to plugging and low loss (high calibration accuracy requirements). |
| 3.3 On-board radar/5G small base station |
| Cable: PTFE insulated foam cable (such as Gore G-FLEX 150) |
| Reason: 6~24GHz low loss demand, outer diameter ≤2mm convenient for wiring. |
| 3.4 Military equipment |
| Cable: RG-316 (military standard MIL-DTL-17) |
| Reason: Resistant to extreme temperature and vibration, high shielding requirements. |
| 4. Supplementary explanation |
| 4.1 Outer diameter mismatch: MCX connectors usually support 1.0~3.0mm wire diameters, and need to be customized beyond the range (such as micro wires, special MCX heads are required). |
| 4.2 High-frequency loss: RG-174 is twice as high as foam PE wire at 6GHz, and long-distance transmission avoids use. |
| 4.3 Phase stability: For phase-sensitive applications (phased arrays), semi-rigid lines or phase-stable cables (such as Huber+Suhner S100) are preferred. |
| 4.4 Connector level: Gold-plated contact MCX (non-nickel-plated) is selected to ensure a life of >500 plugging and unplugging. |
Factory Tour
Adhering to the business principle of mutual benefits, we have had a reliable reputation among our customers because of our professional services, quality products and competitive prices.
Knowledge
What international certifications has your company obtained?
How do you ensure product quality?
Do you provide technical support?
What if products are damaged during shipping?
What is your warranty policy?
How to test product quality before bulk orders?
N180° male head to SMA180° male head
Product Model:
Categories:
Keywords:
Download File:
MOQ:1000pcs
Online Message
Ready to grow your business? Your next great business opportunity starts with an inquiry.