Product introduction
| Product introduction |
| BNC180° male head to BNC180° male head |
| Wire: RG223 RF Coaxial Cable |
| Interface type: BNC |
| Wire length: 5cm~200cm (length can be customized) |
| RG223 RF Coaxial Cable Parameter Description | ||
| 1. Core parameters | ||
| Parameter | Typical value | Standard |
| Characteristic impedance | 50Ω ± 2Ω | Comply with IEEE standards |
| Outside diameter | 5.4mm ±0.2mm | Bending radius: dynamic 54mm/static 27mm |
| Central conductor | 7×0.17mm tinned copper stranded wire | The cross-sectional area is 0.22mm2, taking into account flexibility and conductivity. |
| Insulating materials | Solid polyethylene PE | Dielectric constant 2.3 |
| Shielding layer | Double-layer structure: 1 Tin-plated copper braided layer (coverage rate 96%) 2 Tinned copper braided layer (coverage rate 95%) | Double 95% braided shielding >85dB @1GHz |
| Cover material | Flame-retardant PVC | Oil-resistant/wear-resistant |
| Weight | 48KG/km | Lightweight design |
| 2. Frequency and attenuation | |||
| Frequency | Attenuation (dB/100m) | Compare the advantages of RG58 | Extreme transmission distance |
| 100MHz | 10.5 | Low 18% | 150m |
| 400MHz | 21.8 | Low 22% | 70m |
| 1GHz | 36.2 | Low 25% | 35m |
| 2.4GHz | 59.7 | 30% lower | 20m |
| 3. Electrical performance | |
| Parameter | Value |
| Propagation speed | 66% light speed (VP=0.66) |
| Electric capacity | 101pF/m |
| Working voltage | 1500V RMS (sea level) |
| VSWR | ≤1.3@3GHz |
| 4. Mechanical and environmental characteristics | ||
| Test items | Standard | Bear fruit |
| Tensile strength | MIL-DTL-23329 | ≥600 N |
| Bending fatigue life | 1000 times @5D bending radius | Shielding resistance change <5% |
| Flame retardant | UL 1666 | Self-extinguishing time <30 seconds |
| Temperature cycle | -40℃~+85℃ 100次 | Attenuation fluctuation <3% |
| Salt spray test | 500h/5% NaCl | No corrosion perforation of the outer sheath |
| 5. Typical application scenarios |
| 1. Military communication equipment |
| Field tactical radio jumper (anti-pull/anti-silt) |
| Internal wiring of armored vehicles (passed the MIL-STD-810 vibration test) |
| 2. Industrial control system |
| PLC and RF module connection (factory electromagnetic interference environment) |
| Ship navigation equipment (resistant to salt fog corrosion) |
| 3. Test and measuring instruments |
| Spectrum meter/network analyzer test line (requires double shielding to prevent interference) |
| EMI laboratory benchmark cable |
| Selection guide | |||||
| 1. Commonly used adaptive cable specifications and characteristics | |||||
| Model | Outside diameter | Central conductor | 3GHz loss | Distinguishing feature | Applicable scenarios |
| RG-174 | 2.8mm | 7*0.16mm | 0.82dB/m | Flexible, easy to install, low cost | Consumer electronics |
| RG-316 | 2.6mm | 7*0.1mm | 0.84dB/m | High temperature resistance, military industry standards | High-temperature environment, test instruments |
| Micro-foam PE line | 1.5~2.2mm | 0.3~0.5mm | 0.50dB/m | Low high-frequency loss | 5G/Wi-Fi |
| Semi-steel wire | 1.0~3.0mm | Solid copper | 0.30dB/m | Relatively stable and well shielded | Test calibration, millimeter wave front band |
| 2. Key parameter comparison and selection logic | ||||
| 2.1 Priority of electrical performance | ||||
| Parameter | RG-174 | RG-316 | Foamed PE line | Affect |
| Attenuation @6GHz | 1.8dBm/m | 1.7dBm/m | 0.9dBm/m | High-frequency signal integrity |
| Shielding efficiency | 70dB | 90dB | >90dB | Anti-interference ability |
| Impedance stability | ±3Ω | ±2Ω | ±1Ω | Reflection signal suppression |
| 2.2 Mechanical and environmental adaptability | |||
| Parameter | RG-174 | RG-316 | Foamed PE line |
| Minimum bending radius | 15mm | 25mm | 30mm |
| Temperature tolerance range | -40℃~+85℃ | -65℃~+200℃ | -50℃~+85℃ |
| Tensile strength | Medium | Tall | Low (easy to damage) |
| 3. Typical application scenarios and cable matching |
| 3.1 Consumer electronic products (Bluetooth/Wi-Fi) |
| Cable: RG-174 |
| Reason: cost-sensitive, frequency ≤5GHz, short length (<0.3m) and controllable loss. |
| 3.2 Test instrument jumper (vector network analyzer) |
| Cable: RG-316 or low-loss foam cable (such as Times LMR-200) |
| Reason: It needs to be resistant to plugging and low loss (high calibration accuracy requirements). |
| 3.3 On-board radar/5G small base station |
| Cable: PTFE insulated foam cable (such as Gore G-FLEX 150) |
| Reason: 6~24GHz low loss demand, outer diameter ≤2mm convenient for wiring. |
| 3.4 Military equipment |
| Cable: RG-316 (military standard MIL-DTL-17) |
| Reason: Resistant to extreme temperature and vibration, high shielding requirements. |
| 4. Supplementary explanation |
| 4.1 Outer diameter mismatch: MCX connectors usually support 1.0~3.0mm wire diameters, and need to be customized beyond the range (such as micro wires, special MCX heads are required). |
| 4.2 High-frequency loss: RG-174 is twice as high as foam PE wire at 6GHz, and long-distance transmission avoids use. |
| 4.3 Phase stability: For phase-sensitive applications (phased arrays), semi-rigid lines or phase-stable cables (such as Huber+Suhner S100) are preferred. |
| 4.4 Connector level: Gold-plated contact MCX (non-nickel-plated) is selected to ensure a life of >500 plugging and unplugging. |
Factory Tour
Adhering to the business principle of mutual benefits, we have had a reliable reputation among our customers because of our professional services, quality products and competitive prices.
Knowledge
What international certifications has your company obtained?
How do you ensure product quality?
Do you provide technical support?
What if products are damaged during shipping?
What is your warranty policy?
How to test product quality before bulk orders?
BNC180° male head to BNC180° male head
Product Model:
Categories:
Keywords:
Download File:
MOQ:1000pcs
Online Message